New and Valid for 100% Passing Ensure NetApp NS0-507 Dumps from PassLeader: https://www.passleader.com/ns0-507.html (130 Q&As), PassLeader offer both NS0-507 VCE Dumps and NS0-507 PDF Dumps for Preparing for the NetApp NS0-507 Exam, 100% Valid and 100% Passing Guarantee.
More, you can download the latest PassLeader NS0-507 Exam Dumps Online for FREE: https://drive.google.com/open?id=0B-ob6L_QjGLpSmd3OXVGOE5FODQ
QUESTION 11
A storage administrator wants to ensure multipathing between the initiator and the target. The current connection uses target portal group 1027. Referring to the exhibit, which IP address should be used to accomplish this task?
A. 192.168.0.53
B. 192.168.0.165
C. 192.168.0.167
D. 192.168.0.166
Answer: D
QUESTION 12
You want to configure iSCSI on a 4-node cluster that only has NFS configured. You need to guarantee that you have at least two optimized paths per LUN. In this scenario, what are the minimum number of iSCSI LIF needed?
A. 6
B. 4
C. 8
D. 2
Answer: C
QUESTION 13
Referring to the exhibit, which design solution is shown?
A. single-fabric HA pair
B. multifabric single-node
C. single-fabric single-node
D. multifabric HA pair
Answer: D
QUESTION 14
You have 4-node cluster with a FAS8200 HA pair and AFF A700 HA PAIR. You need to move a LUN from the FAS8200 to the AFF A700 for faster performance. In this scenario, which sequence of steps, accomplishes task nondisruptively?
A. 1. Remove the FAS8200 HA pair from file reporting-nodes list.
2. Add the AFF-A700 HA pair to the reporting nodes list.
3. Run the lun move command.
B. 1. Add the AFF A700 HA pair to the reporting-nodes list.
2. Run the lun move command.
3. Remove the FAS8200 HA pair from the reporting-nodes list.
C. 1. Run the lun move command.
2. Add the AFF A700 H pair to the repotting-nodes list.
3. Remove the FAS8200 HA pair from the reporting-nodes.
D. 1. Add the AFF A700 HA pair to the reporting-nodes list.
2. Remove the FAS8200 HA pair from the reporting-nodes list.
3. Run the lun move command.
Answer: B
QUESTION 15
You are planning a migration from a 7-mode system running DATA ONTAP 8.0 to a new AFF A700 ONTAP 9.1 system. This 7-mode system provides only iSCSI LUNs for a windows server 2012R2 server farm. There is no FC fabric available for this migration. In this scenario, what would you use for the migration?
A. Foreign LUN import (FLI)
B. Unified Host Utility Kit
C. 7-mode Transition tool (7MTT)
D. OnCommand System Manager
Answer: C
QUESTION 16
When using the GUID Partition Table for a Windows Server 2016 system, which LUN type would be used?
A. windows_gpt
B. windows_2008
C. windows
D. linux
Answer: A
QUESTION 17
An administrator has an ONTAP cluster configured for SAN use. There are no port sets configured on the cluster. The SAN is configured as dual-fabric, with no zones defined on the switches. Referring to the exhibit, which two statements describe the host-to-storage connectivity? (Choose two.)
A. DM-MP is in use
B. Each FAS9000 node has 4 targets ports per fabric
C. Each FAS9000 node has 2 targets ports per fabric
D. There are eight optimized paths from host to storage
Answer: AB
QUESTION 18
For host connections to ONTAP storage, which three components are used as queries in the Netapp Interoperability Matrix Tool (IMT)? (Choose three.)
A. Firmware
B. Adapter model
C. Driver
D. SFP+
E. Optical cable
Answer: ABC
QUESTION 19
A customer wants to set up storage so that the LUNs have no possibility to go offline. There are multiple LUNs per volume. There should be extra available space in the volume for snapshot copies. Which two configuration settings would accomplish task? (Choose two.)
A. Volume guarantee = volumeLUN reservation = enabledFractional reservation =100%Snapshot autodelete = disabledAutogrow = enabled
B. Volume guarantee = noneLUN reservation = enabledFractional reservation =0Snapshot autodelete = enabledAutogrow = enabled
C. Volume guarantee = volumeLUN reservation = enabledFractional reservation =0Snapshot autodelete = disabledAutogrow = disabled
D. Volume guarantee = volumeLUN reservation = enabledFractional reservation =100%Snapshot autodelete = enabledAutogrow = disabled
Answer: AD
QUESTION 20
You are planning to expand an existing SAN only cluster consisting of eight AFF A700 nodes. In this scenario, that is the maximum number of additional AFF A700 nodes allowed for your cluster?
A. 8
B. 4
C. 12
D. 0
Answer: B
Explanation:
AFF700 can support a max of 12 nodes for SAN connections. As such the answer is B – 4 nodes can be added to the existing 8 node cluster!
Trying the PassLeader NS0-507 Dumps in VCE and PDF for Your First Attempt and 100% Passing: https://www.passleader.com/ns0-507.html (130 Q&As, VCE and PDF)
More, download new PassLeader NS0-507 Exam Dumps for FREE: https://drive.google.com/open?id=0B-ob6L_QjGLpSmd3OXVGOE5FODQ