New and Valid for 100% Passing Ensure NetApp NS0-502 Dumps from PassLeader: https://www.passleader.com/ns0-502.html (109 Q&As), PassLeader offer both NS0-502 VCE Dumps and NS0-502 PDF Dumps for Preparing for the NetApp NS0-502 Exam, 100% Valid and 100% Passing Guarantee.
More, you can download the latest PassLeader NS0-502 Exam Dumps Online for FREE: https://drive.google.com/open?id=0B-ob6L_QjGLpa2F6c3dmQXJFcDQ
QUESTION 1
Referring to the exhibit. Given the information provided in the diagram, what is the appropriate FC topology?
A. point-to-point
B. switched fabric
C. arbitrated loop
D. ring
Answer: B
QUESTION 2
Which FC SAN topology provides the best performance and scalability?
A. cascade
B. core-edge
C. full mesh
D. partial mesh
Answer: B
QUESTION 3
A 200-GB LUN is created in an empty 500-GB volume with the volume guarantee option set to Volume. LUN reservation is enabled and the fractional reserve is set to 100 and scheduled snapshots are disabled. Directly after LUN creation, what is the maximum free space available in the volume?
A. 200 GB
B. 300 GB
C. 400 GB
D. 500 GB
Answer: B
QUESTION 4
Referring to the exhibit. Based on the diagram shown, what is the appropriate FC switch topology?
A. full mesh
B. core-edge
C. full cascade
D. partial mesh
Answer: B
QUESTION 5
Referring to the exhibit. Based on the diagram shown, what is the appropriate FC switch topology?
A. core-edge
B. full mesh
C. partial mesh
D. partial cascade
Answer: C
QUESTION 6
A 100-GB thinly provisioned LUN is allocated to a Windows host. 100 GB of data is written into the LUN. The current capacity utilization on the disk array as well as the host is 100%. 50 GB of data is deleted from the LUN. Space reclaimer has NOT been run. What is the current capacity utilization on both the host and the disk array?
A. 50% on the host, 100% on the disk array
B. 100% on the host, 50% on the disk array
C. 50% on the host, 50% on the disk array
D. 100% on the host, 100% on the disk array
Answer: A
QUESTION 7
A customer has a four-node SUN cluster configuration. Each node has two, dual-ported HBAs. What is the minimum number of igroups that need to be created to map a LUN to the cluster?
A. 1
B. 2
C. 4
D. 8
Answer: A
QUESTION 8
A company has FC patch panels in their data center. They plan on using them to interconnect their storage controllers to the FC switches and the hosts using the storage. They have 62.5 micron cable between the patch panels. Which cable should you use on the NetApp storage controller’s Target Ports to make this a supported configuration?
A. long wave SFPs, 62.5 micron FC cable
B. short wave SFPs, 50 micron FC cable
C. short wave SFPs, 62.5 micron FC cable
D. long wave SFPs, 50 micron FC cable
Answer: C
Trying the PassLeader NS0-502 Dumps in VCE and PDF for Your First Attempt and 100% Passing: https://www.passleader.com/ns0-502.html (109 Q&As, VCE and PDF)
More, download new PassLeader NS0-502 Exam Dumps for FREE: https://drive.google.com/open?id=0B-ob6L_QjGLpa2F6c3dmQXJFcDQ